2000W Pure Sine Wave Inverter For Home Use 12V 24V 48V To 110V 220V
Features
1. Pure sine wave output ( THD < 3% ).
2. Input & output completely isolated design.
3. High efficiency 93%.
4. Loading and temperature controlled the cooling fan.
5. Protection: input low voltage alarm & shutdown, overload, short circuit.
6. Input over voltage, over temperature, reverse polarity.
7. USB output port 5V 2.1A.
8. With Remote controller function /CR80 /CRD80 /CRD99 Remote controller with 5m cable optional, wireless remote controller optional.
9. LCD display function optional.
10. 2 years quality warranty, technical supporting whole life.
More Details
| MODEL | FS2000-112 | FS2000-124 | FS2000-148 | FS2000-212 | FS2000-224 | FS2000-248 | |
| Output | AC Voltage | 100/110/120VAC | 220/230/240VAC | ||||
| Rated Power | 2000W | ||||||
| Surge Power | Load 120~150%(3min.);4000W(3sec;resistive) | ||||||
| Waveform | Pure Sine Wave(THD<3%) | ||||||
| Frequency | 50/60Hz ±0.05% | ||||||
| AC Regulation | ±5% | ±10% | |||||
| Power Factor Allowed | COSθ-90°~COSθ+90° | ||||||
| Standard Receptacles | USA/British/Franch/Schuko /UK/Australia/Universal etc. optional | ||||||
| LED Indicator | Green for power on, red for faulty status | ||||||
| USB port | 5V 2.1A | 5V 2.1A | —— | 5V 2.1A | 5V 2.1A | —— | |
| LCD display | voltage, power, protection status ( optional) | ||||||
| Remote control function | default | ||||||
| Remote controller | CR80/CRD80 optional | ||||||
| Input | No Load Current Draw | ≤1.1A | ≤0.80A | ≤0.70A | ≤1.1A | ≤0.80A | ≤0.70A |
| DC Voltage | 12VDC | 24VDC | 48VDC | 12VDC | 24VDC | 48VDC | |
| Voltage Range | 10.5~15VDC | 21~30VDC | 42~60VDC | 10.5~15VDC | 21~30VDC | 42~60VDC | |
| Efficiency(Typ.) | 89%~93% | ||||||
| Fuse | 40A×8 | 20A×8 | 10A×8 | 40A×8 | 20A×8 | 10A×8 | |
| Remote Control | Function (optional) | ||||||
| Protection | BAT. Low Alarm | 10.5±0.5VDC | 21±1.0VDC | 42±2.0VDC | 10.5±0.5VDC | 21±1.0VDC | 42±2.0VDC |
| BAT. Low Shutdown | 10±0.5VDC | 20±1.0VDC | 40±2.0VDC | 10±0.5VDC | 20±1.0VDC | 40±2.0VDC | |
| Over Load | Shut down output voltage , restart to recover | ||||||
| Over Voltage | 15.5±0.5VDC | 31±1.0VDC | 62±2.0VDC | 15.5±0.5VDC | 31±1.0VDC | 62±2.0VDC | |
| Over Temperature | Shut down output voltage , recover automatically after temperature goes down | ||||||
| Output Short | Shut down output voltage , restart to recover | ||||||
| DC Input Reverse Polarity | By fuse | ||||||
| Earth Fault | Shut off o/p when the load has electrical leakage | ||||||
| Soft Start | Yes, 3-5 Seconds | ||||||
| Environment | Working Temp. | 0~+50℃ | |||||
| Working Humidity | 20~90%RH non-condensing | ||||||
| Storage Temp.&Humidity | -30~+70℃,10~95%RH | ||||||
| Safety & EMC | Safety Standards | Certified UL 458(only for “GFCI” receptacles) | Certified EN 60950-1; 2006+A11: 2009+A1: 2010+A12: 2011+A2: 2013. | ||||
| Isolation Resistance | I/P-O/P:100M Ohms/500VDC | ||||||
| EMI Conduction & | Certified FCC class A | Certified EN 62040-2:2006,EN61000-3-2; EN61000-3-3; | |||||
| Radiation | |||||||
| EMS Immunity | —— | Certified IEC61000-4-3, IEC61000-4-6 | |||||
| E-MARK | —— | Certified ECE RIO.05:2014 | |||||
| Others | Dimension(L×W×H) | 325.2×281.3×112.7mm | |||||
| Packing | 5.5kg;2pcs/11.8kg/0.053m³ | ||||||
| Cooling | Load control fan or by thermal control fan | ||||||
| Application | Home and Office appliances,Portable Power Equipment,Vehicle,Yacht and Off-Gid Solar | ||||||
| power systems…etc. | |||||||